Porosity — Valence-Dependent Electrical Conductivity in a 3D Tetrahydroxyquinone-Based Metal-Organic Framework

Measurement evidence

Porosity

Valence-Dependent Electrical Conductivity in a 3D Tetrahydroxyquinone-Based Metal-Organic Framework · Chen G., Gee L.B., Xu W. et al. · Journal of the American Chemical Society · 2020 · 21243-21248

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

N2 adsorption isotherm and BET surface-area analysis

FeTHQ activated for BET · Powder

FeTHQ degassed at 60 deg C for 2 h followed by 100 deg C for 8 h.

Atmosphere
N2 adsorption after vacuum degassing
Context
activated pristine FeTHQ powder
Measurement source
21244 · main text · Figure 2d and Figure S7
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
BET surface area~163 m2 g^-1Text
Approximate
21244 · main text · Figure 2d
Calculated cavity radius3.726 ACaption
Exact Reported
S7 · Figure S7 caption · Figure S7