Mechanical testing on Shimadzu AGS-X at room temperature
CNF@Ni-HITP nanopaper · Electrode
Tensile stress and Young's modulus of CNF@c-MOF nanopapers from stress-strain curves in SI.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CNF@c-MOF nanopaper tensile stressMarked as a best value within this paper | up to 350 MPa | — | — | Text Approximate | rendered page 4 / article p.9581 · Results and Discussion · Figure S8 |
| CNF@c-MOF nanopaper Young's modulusMarked as a best value within this paper | up to 10 GPa | — | — | Text Approximate | rendered page 4 / article p.9581 · Results and Discussion · Figure S8 |