Electrical Transport — Electrically Conducting Redox-Complementary Dual-Ligand 2D Graphitic MOF with Orthogonal Charge Transport Pathways

Measurement evidence

Electrical Transport

Electrically Conducting Redox-Complementary Dual-Ligand 2D Graphitic MOF with Orthogonal Charge Transport Pathways · Zhang S., Zhang W., Yadav A. et al. · Advanced Electronic Materials · 2025 · e00319

4 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Temperature-dependent I-V and Arrhenius analysis

CDL-MOF1 pressed pellet · Pellet

Same pellet setup immersed in temperature-controlled sand bath; devices held 30 min at each temperature; Figure S6 shows CDL-MOF1 I-V plots from 298-358 K.

Temperature
298-358
Atmosphere
ambient
Geometry
Two-probe pressed pellet
Context
pristine target and parent control pellets
Measurement source
p003 / SI p.S2 · General Materials and Methods · Figure 5b; Figure S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Thermally activated charge transportthermally activated charge transport; semiconducting behaviorText
Qualitative
p005-p006 / article pp.5-6 · Results and Discussion · Figure 5b; Figure S6
CDL-MOF1 thermal activation energyMarked as a best value within this paperEa = 0.17 eVText
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5b
Cu3(HHTP)2 thermal activation energyEa = 0.13 eVFigure Axis
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5b
Cu3(HHTQ)2 thermal activation energyEa = 0.30 eVFigure Axis
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5b

Two-probe direct current-voltage (I-V) pellet conductivity

CDL-MOF1 pressed pellet · Pellet

Pressed pellets under ambient conditions; stainless-steel rods with flat round tips radius 0.135 cm; silver paint contacts; L approx 0.02 cm; area 0.057 cm2; 3-5 devices.

Temperature
295
Atmosphere
ambient
Geometry
Two-probe pressed pellet in Teflon tube between silver-coated stainless-steel rods
Context
pristine target framework pellet
Measurement source
p005 / article p.5 · Results and Discussion · Figure 5a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CDL-MOF1 average room-temperature pellet conductivitysigma_average = 0.11 (+/- 0.01) S m-1 at 22 deg C0.11 S m-1+/- 0.01 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a
CDL-MOF1 highest room-temperature pellet conductivityMarked as a best value within this papersigma_highest = 0.12 S m-1 at 22 deg C / 295 K0.12 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a
CDL-MOF1 bulk conductivity in SI Table S10.17 (bulk) S/m0.17 S m-1SI Table
Exact Reported
p005 / SI p.S4 · Table S1 · Table S1
All three MOFs show ohmic I-V behaviourlinear current-voltage plotsText
Qualitative
p005 / article p.5 · Results and Discussion · Figure 5a

Two-probe direct current-voltage (I-V) pellet conductivity

Cu3(HHTP)2 pressed pellet · Pellet

Parent Cu3(HHTP)2 pellet measured under the same two-probe conditions as CDL-MOF1.

Temperature
295
Atmosphere
ambient
Geometry
Two-probe pressed pellet in Teflon tube between silver-coated stainless-steel rods
Context
pristine parent control pellet
Measurement source
p005 / article p.5 · Results and Discussion · Figure 5a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu3(HHTP)2 average room-temperature pellet conductivitysigma_average = 6.5 (+/- 0.8) x 10^-2 S m-10.065 S m-1+/- 0.008 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a
Cu3(HHTP)2 highest room-temperature pellet conductivityMarked as a best value within this papersigma_highest = 7.3 x 10^-2 S m-10.073 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a

Two-probe direct current-voltage (I-V) pellet conductivity

Cu3(HHTQ)2 pressed pellet · Pellet

Parent Cu3(HHTQ)2 pellet measured under the same two-probe conditions as CDL-MOF1.

Temperature
295
Atmosphere
ambient
Geometry
Two-probe pressed pellet in Teflon tube between silver-coated stainless-steel rods
Context
pristine parent control pellet
Measurement source
p005 / article p.5 · Results and Discussion · Figure 5a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu3(HHTQ)2 average room-temperature pellet conductivitysigma_average = 3.9 (+/- 2.0) x 10^-4 S m-10.00039 S m-1+/- 0.00020 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a
Cu3(HHTQ)2 highest room-temperature pellet conductivityMarked as a best value within this papersigma_highest = 5.9 x 10^-4 S m-10.00059 S m-1Text
Exact Reported
p005 / article p.5 · Results and Discussion · Figure 5a