Electrical Transport — Synthesis, conductivity, and electromagnetic wave absorption properties of chiral poly Schiff bases and their silver complexes

Measurement evidence

Electrical Transport

Synthesis, conductivity, and electromagnetic wave absorption properties of chiral poly Schiff bases and their silver complexes · Li H., Liu C., Dai B. et al. · Journal of Applied Polymer Science · 2015 · 42498

9 measurement groups · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Complex 1a pressed tablet / dried black powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity7.2 x 10^-4 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Complex 1b pressed tablet / dried black powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity2.4 x 10^-4 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Complex 2a pressed tablet / dried black powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity1.3 x 10^-5 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Complex 3a pressed tablet / dried brown powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity11.7 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Complex 4a pressed tablet / dried black powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivityMarked as a best value within this paper3.7 x 10^2 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Polymer 1 pressed tablet / dried gray powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity3.7 x 10^-10 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Polymer 2 pressed tablet / dried brown powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity8.0 x 10^-11 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Polymer 3 pressed tablet / dried buff powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity2.4 x 10^-10 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I

Room-temperature conductivity; RTS-8x four-probe apparatus for higher-conductivity range and AS-31356 AC conductivity tester with copper contacts for low-conductivity range.

Polymer 4 pressed tablet / dried gray powder · Pellet

Pressed tablet, approximately 1 mm thick, prepared at 15 MPa; room temperature.

Temperature
room temperature
Atmosphere
ambient/not specified
Geometry
pressed tablet with electrical contacts
Context
neat polymer or neat silver complex
Measurement source
2 · Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature electrical conductivity3.9 x 10^-10 S/cmTable
Exact Reported
4 · Conductivity Analysis · Table I