Porosity — Dimensionality Modulates Electrical Conductivity in Compositionally Constant One-, Two-, and Three-Dimensional Frameworks

Measurement evidence

Porosity

Dimensionality Modulates Electrical Conductivity in Compositionally Constant One-, Two-, and Three-Dimensional Frameworks · Chen T., Dou J.-H., Yang L. et al. · Journal of the American Chemical Society · 2022 · 5583-5593

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

N2 adsorption isotherm, BET analysis; Zeo++ geometric analysis

Activated Ni-3D-ox · Powder

Sample activated at 100 C under high dynamic vacuum (<10^-4 mbar) for 24 h before N2 isotherm at 77 K; additional main-text discussion of activation at 110 C.

Temperature
77
Atmosphere
N2 adsorbate; high-vacuum activation
Context
Ni-3D-ox activated porous framework
Measurement source
SI pp.4,38-39 · N2 adsorption isotherms; Figures S24-S25 · Figures S24-S25
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni-1D BET surface area33.57 +/- 0.28 m2/g+/- 0.28Caption
Exact Reported
SI p.38 · Figure S24 · Figure S24
Ni-3D-ox BET apparent surface area119.61 +/- 0.46 m2/g+/- 0.46Caption
Exact Reported
SI p.38 · Figure S24 · Figure S24
Ni-3D-ox theoretical solvent-accessible surface area518 m2/gText
Exact Reported
SI p.39 · Figure S25 discussion · Figure S25