OER durability: post-CV LSV and chronoamperometry
Co1Fe1-B-P · Nanosheet
3000 CV cycles from 1.2 to 1.5 V vs RHE at 100 mV s-1; 20 h chronoamperometry at potential corresponding to 10 mA cm-2.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| chronoamperometry durability duration | 20 h with negligible current decay | — | — | Text Exact Reported | 6 · Results and discussion · Fig. 4f |
| CV cycling durability | 3000 cycles with no obvious potential shift | — | — | Text Exact Reported | 6 · Results and discussion · Fig. 4e |