Electrical Transport — Piperazine-linked metal covalent organic framework-coated fibers for efficient electro-enhanced solid-phase microextraction of chlorophenols

Measurement evidence

Electrical Transport

Piperazine-linked metal covalent organic framework-coated fibers for efficient electro-enhanced solid-phase microextraction of chlorophenols · Wang J., Zhang W., Chen H. et al. · Journal of Chromatography A · 2023 · 463847

2 measurement groups · 4 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Cyclic voltammetry used as conductivity evidence

CuPc-MCOF-coated stainless steel fibre · Electrode

Reversible Fe2+/Fe3+ redox system; solution containing 0.01 mM [Fe(CN)6]3+/4+ and 0.1 M KCl.

Geometry
CuPc-MCOF-modified electrode/coated fibre
Context
composite coated fibre/electrode; pristine framework is active conductive coating
Measurement source
p.4-p.5 · 3.1. Synthesis and characterization · Fig. 2c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Approximate anodic peak current from CVapproximately 1.3 x 10^-4 AVisual Estimate
Uncertain
p.5 · Fig. 2 · Fig. 2c
CV conductivity evidenceredox peaks with good peak shapeQualitative
Qualitative
p.4 · 3.1. Synthesis and characterization · Fig. 2c

Electrochemical impedance spectroscopy (EIS)

CuPc-MCOF-coated stainless steel fibre · Electrode

Nyquist plot in 0.01 mM [Fe(CN)6]3+/4+ and 0.1 M KCl; excitation signal 5 mV; formal potential 220 mV; frequency 1.0e-2 to 1.0e5 Hz.

Geometry
CuPc-MCOF-modified electrode/coated fibre
Context
composite coated fibre/electrode; pristine framework is active conductive coating
Measurement source
p.5 · Figure caption and 3.1. Synthesis and characterization · Fig. 2d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
EIS electron-transfer resistance evidencesmaller Nyquist semicircle diameter; lower electron transfer resistanceQualitative
Qualitative
p.4 · 3.1. Synthesis and characterization · Fig. 2d
Approximate Nyquist semicircle diameterapproximately 350 ohmrough visual estimate from axisVisual Estimate
Uncertain
p.5 · Fig. 2 · Fig. 2d