Electrical Transport — Bi-porous metal-organic framework with hydrophilic and hydrophobic channels: Selective gas sorption and reversible iodine uptake studies

Measurement evidence

Electrical Transport

Bi-porous metal-organic framework with hydrophilic and hydrophobic channels: Selective gas sorption and reversible iodine uptake studies · Chaudhari A.K., Mukherjee S., Nagarkar S.S. et al. · CrystEngComm · 2013 · 9465-9471

2 measurement groups · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

DC electrical conductivity on pressed pellets; SI describes conventional four-probe method using current-voltage fits

iodine-loaded compound 1' subset nI2 · Pellet

Room-temperature current-voltage characteristics; Ohmic linear fits after iodine inclusion.

Temperature
room temperature
Geometry
pressed pellet
Context
iodine-loaded guest framework compared against pristine 1'
Measurement source
p011 · Details of Iodine inclusion study and electrical conductivity measurement · Fig. S10
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DC electrical conductivity of iodine-loaded 1' subset nI2Marked as a best value within this paper1.298 x 10-6 S cm-10.0001298 S m-1Text
Exact Reported
p004 / 9468 · Results and discussion · Fig. S10
conductivity enhancement after iodine inclusionMarked as a best value within this paperabout 76 timesText
Rounded Reported
p011 · Details of Iodine inclusion study and electrical conductivity measurement · Fig. S10

DC electrical conductivity on pressed pellets; SI describes conventional four-probe method using current-voltage fits

guest-free activated compound 1' · Pellet

Room-temperature current-voltage characteristics; Ohmic linear fits.

Temperature
room temperature
Geometry
pressed pellet
Context
guest-free activated pristine framework
Measurement source
p011 · Details of Iodine inclusion study and electrical conductivity measurement · Fig. S10
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DC electrical conductivity of activated 1'Marked as a best value within this paper1.714 x 10-8 S cm-10.000001714 S m-1Text
Exact Reported
p004 / 9468 · Results and discussion · Fig. S10