electrochemical impedance spectroscopy
2-CPE · Electrode
EIS comparison of {P2W18O62}-CPE, 1-CPE and 2-CPE; high-frequency Z' intercept/Rs discussed qualitatively. SI general methods report EIS frequency range 0.01 Hz to 100 kHz.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|