Double-layer capacitance from CV scan-rate dependence
Co-HITP nanosheets (Co-HITP NSs) · Nanosheet
Non-Faradaic potential window, scan rates 2-10 mV s^-1; Cdl extracted from j vs scan-rate slope.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Double-layer capacitance for Co-HITP NSs | 1.01 mF cm-2 | — | — | Figure Axis Rounded Reported | p005 / 42277 · Results and discussion · Fig. 3g |