Ex situ XRD and SEM before/after charging and after cycling
Ni3(HITP)2 electrode on copper foil · Electrode
Film electrodes on Cu foil before and after charge were characterised by XRD; SEM before charge and after 10 charge/discharge cycles.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| SEM morphology after 10 cycles | spindle morphology maintained well after 10 cycles | — | — | Text Qualitative | 3 · Supplementary data · Figure S4 |
| ex situ electrode XRD conductive carbon peak | 26.5 degrees 2-theta, attributed to conductive carbon | — | — | Text Exact Reported | 5 · Results and discussion · Figure S3 |
| ex situ electrode XRD metallic Cu peak | 43.3 degrees 2-theta, related to metallic Cu from Cu foil collector | — | — | Text Exact Reported | 5 · Results and discussion · Figure S3 |
| ex situ electrode XRD CuOx peak | 18.2 degrees 2-theta, related to CuOx from Cu foil collector | — | — | Text Exact Reported | 5 · Results and discussion · Figure S3 |
| XRD after charge structural retention | XRD patterns before and after charge are similar; Ni3(HITP)2 peaks between 4.7 and 15 degrees retained | — | — | Text Qualitative | 2 · Supplementary data · Figure S3 |