Sensing Application — A Humidity-Induced Large Electronic Conductivity Change of 107 on a Metal-Organic Framework for Highly Sensitive Water Detection

Measurement evidence

Sensing Application

A Humidity-Induced Large Electronic Conductivity Change of 107 on a Metal-Organic Framework for Highly Sensitive Water Detection · Deng W.-H., Li Q.-H., Chen J. et al. · Angewandte Chemie - International Edition · 2023 · e202305977

1 measurement group · 13 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

DC chemiresistive humidity sensing

Drop-cast H2SO4@(NH2)2-MIL-125 humidity sensor · Electrode

Humidity sensing from 5-100 percent RH and 0-5 percent RH at room temperature, 1 V bias, 600 sccm flow for 5-100 percent RH

Temperature
298
Atmosphere
dry air/humidified air for 5-100 percent RH; dry N2 carrier for 0-5 percent RH
Geometry
drop-cast MOF on Ad-Pd interdigital electrodes on Al2O3 substrate
Context
target sensor compared with MIL-125, NH2-MIL-125 and (NH2)2-MIL-125 sensors
Measurement source
4 · S1.4 Evaluation of Sensing Performance · Figures 3, S10-S16; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
experimental limit of detection in ppm H2OMarked as a best value within this paper20 ppm H2OText
Rounded Reported
4 · Results · Figure 3b
experimental limit of detectionMarked as a best value within this paper0.06% RHSI Table
Exact Reported
12 · S2.7 Chemiresistor Sensor Performance · Table S3
humidity sensing range upper boundMarked as a best value within this paper100% RHText
Exact Reported
4 · Results · Figure 3a; Table S3
humidity sensing range lower boundMarked as a best value within this paper0.06% RHText
Exact Reported
4 · Results · Figure 3b; Table S3
recovery time0.3 minText
Exact Reported
4 · Results · Figure 3b inset
repeatability coefficient of variationCV as low as 6.7%Text
Exact Reported
4 · Results · Figure S14
response at 100% RHMarked as a best value within this paper1.6 x 10^10 / 100 RH%SI Table
Rounded Reported
12 · S2.7 Chemiresistor Sensor Performance · Table S3
response at 50% RHMarked as a best value within this paper2.3 x 10^7Text
Rounded Reported
4 · Results · Figure 4b; Table S3
response at 5% RHMarked as a best value within this paper1.6 x 10^3Text
Rounded Reported
4 · Results · Figure 4b; Table S3
response at 90% RHMarked as a best value within this paper1.2 x 10^8Text
Rounded Reported
4 · Results · Figure 4b; Table S3
response time4.8 minText
Exact Reported
4 · Results · Figure 3b inset
selectivity factor against strongest interferenceas high as 13Text
Rounded Reported
4 · Results · Figures 3c, S12, S13
long-term stability test durationtested for over 8 monthsoverText
Approximate
4 · Results · Figure 3c-down