Microscopy Morphology — MOF matrix isolation: Cooperative conformational mobility enables reliable single crystal transformations

Measurement evidence

Microscopy Morphology

MOF matrix isolation: Cooperative conformational mobility enables reliable single crystal transformations · Peralta R.A., Huxley M.T., Young R.J. et al. · Faraday Discussions · 2021 · 84-99

5 measurement groups · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

energy-dispersive X-ray spectroscopy (EDX)

MnMOF-1-DEE after attempted Rh metalation · Single Crystal

EDX measured Mn:Rh ratio/Rh occupancy after attempted post-synthetic Rh metalation.

Context
guest-loaded
Measurement source
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Rh occupancy standard error2.5——SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
Rh occupancy3—2.5%SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1

energy-dispersive X-ray spectroscopy (EDX)

MnMOF-1-THF after attempted Rh metalation · Single Crystal

EDX measured Mn:Rh ratio/Rh occupancy after attempted post-synthetic Rh metalation.

Context
guest-loaded
Measurement source
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Rh occupancy standard error1.5——SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
Rh occupancy5—1.5%SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1

energy-dispersive X-ray spectroscopy (EDX)

Rh-metalated MnMOF-1 from acetone · Single Crystal

EDX measured Mn:Rh ratio/Rh occupancy after attempted post-synthetic Rh metalation.

Context
guest-loaded
Measurement source
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Rh occupancy standard error4.7——SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
Rh occupancyMarked as a best value within this paper210—4.7%SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1

energy-dispersive X-ray spectroscopy (EDX)

Rh-metalated MnMOF-1 from DCM · Single Crystal

EDX measured Mn:Rh ratio/Rh occupancy after attempted post-synthetic Rh metalation.

Context
guest-loaded
Measurement source
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Rh occupancy standard error4.3——SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
Rh occupancyMarked as a best value within this paper198—4.3%SI Table
Exact Reported
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1

energy-dispersive X-ray spectroscopy (EDX)

Rh-metalated MnMOF-1 from p-xylene · Single Crystal

EDX measured Mn:Rh ratio/Rh occupancy after attempted post-synthetic Rh metalation.

Context
guest-loaded
Measurement source
p020 / SI page 20 · SI 6.0 Energy Dispersive X-ray Analysis (EDX) · Table S6.1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
EDX Rh/Mn outcomeRh:Mn = 2:3——Text
Rounded Reported
p008 / journal page 91 · Post-synthetic metalation of MnMOF-1 with [Rh(CO)2Cl]2 · ESI Table S6.1