Thermogravimetric analysis (TGA) and flammability test
Optimised ILE@MOF ionogel, 1.5 g ILE per 1.0 g MOF · Thin Film
TGA under Ar flow from ambient to 700 deg C at 10 deg C min-1; electronic Bunsen burner flame test.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Flame exposure duration without ignition | 60 s | — | — | Text Exact Reported | 9532 · Results and discussion · Fig. 1f inset |
| Flame-test temperature | 1300 deg C flame | — | — | Text Rounded Reported | 9532 · Results and discussion · Fig. 1f inset |
| Onset of decompositionMarked as a best value within this paper | 325 deg C | — | — | Text Exact Reported | 9532 · Results and discussion · Fig. 1f; Table S2 |