Powder X-ray diffraction (XRD), Cu Kalpha radiation
Cu-HHTP nanorod powder · Powder
2theta range 3-40 deg; Philips X'Pert Pro Super diffractometer; compared with Ni-HITP and Cu-HITP.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| XRD [001] peak | 28.1 deg 2theta | — | — | Text Rounded Reported | 2 · 3.1 Morphology and structure characterization · Fig. 1a |
| XRD [100] peak | 4.7 deg 2theta | — | — | Text Rounded Reported | 2 · 3.1 Morphology and structure characterization · Fig. 1a |
| XRD [200] peak | 9.7 deg 2theta | — | — | Text Rounded Reported | 2 · 3.1 Morphology and structure characterization · Fig. 1a |
| XRD [210] peak | 12.7 deg 2theta | — | — | Text Rounded Reported | 2 · 3.1 Morphology and structure characterization · Fig. 1a |