chemiresistive conductance response at constant 1.0 V
Cu3(C6O6)2 chemiresistive device on gold IDE · Electrode
NH3, H2S, NO diluted from 1% tanks in dry N2; 1-40 ppm or 1%; target exposure 10 min and N2 purge 20 min unless specified
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| 1% H2S response multiplier versus 40 ppm | 103 times higher | — | — | Text Exact Reported | 4 · Electrical Response |
| 1% NH3 response multiplier versus 40 ppm | 8 times higher | — | — | Text Exact Reported | 4 · Electrical Response |
| 1% NO response multiplier versus 40 ppm | 25 times higher | — | — | Text Exact Reported | 4 · Electrical Response |
| H2S apparent rate constant | 1.23 min-1 | — | — | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| H2S recovery after N2 purge | 25 % | — | — | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| H2S response at 40 ppm after 10 minMarked as a best value within this paper | 79.4 +/- 3.1 % | — | +/- 3.1 % | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| H2S calibration slope, Figure 2e | y = 1.35x + 1.80; R2 = 0.98 | — | — | Visual Estimate Exact Reported | 3 · Electrical Response · Figure 2 |
| H2S LOD, main textMarked as a best value within this paper | 25 ppb | — | — | Text Rounded Reported | 4 · Electrical Response · Figure 2 |
| H2S LOD, SI Figure S6 | 25.1 ppb | — | — | Caption Exact Reported | S9 · Chemiresistive Tests · Figure S6 |
| NH3 LOD, main text/Figure 2Marked as a best value within this paper | 14 ppb | — | — | Text Exact Reported | 4 · Electrical Response · Figure 2 |
| NH3 LOD, SI Figure S6 | 8.3 ppb | — | — | Caption Exact Reported | S9 · Chemiresistive Tests · Figure S6 |
| NO LOD, main textMarked as a best value within this paper | 13 ppb | — | — | Text Rounded Reported | 4 · Electrical Response · Figure 2 |
| NO LOD, SI Figure S6 | 12.8 ppb | — | — | Caption Exact Reported | S9 · Chemiresistive Tests · Figure S6 |
| NH3 pseudo-first-order rate constant | 4.78 min-1 | — | — | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| NH3 recovery after N2 purge | 93 % | — | — | Visual Estimate Exact Reported | 3 · Electrical Response · Figure 2 |
| NH3 response at 40 ppm saturationMarked as a best value within this paper | 84.2 +/- 1.6 % | — | +/- 1.6 % | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| NH3 calibration slope, Figure 2d | y = 4.00x - 5.86; R2 = 0.98 | — | — | Visual Estimate Exact Reported | 3 · Electrical Response · Figure 2 |
| NO pseudo-first-order rate constant | 0.73 min-1 | — | — | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| NO response drop/recovery after N2 purge | 53 % | — | — | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| NO response at 40 ppm after 10 minMarked as a best value within this paper | -697.3 +/- 42.2 % | — | +/- 42.2 % | Text Exact Reported | 3 · Electrical Response · Figure 2 |
| NO calibration slope, Figure 2f | y = -12.04x - 12.03; R2 = 0.95 | — | — | Visual Estimate Exact Reported | 3 · Electrical Response · Figure 2 |