Electrical Transport — Stabilization of Hexaaminobenzene in a 2D Conductive Metal-Organic Framework for High Power Sodium Storage

Measurement evidence

Electrical Transport

Stabilization of Hexaaminobenzene in a 2D Conductive Metal-Organic Framework for High Power Sodium Storage · Park J., Lee M., Feng D. et al. · Journal of the American Chemical Society · 2018 · 10315-10323

1 measurement group · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Four-point-probe bulk electrical conductivity on pressed pellets

Pressed Co-HAB-D pellet · Pellet

Cold-isostatically pressed pellets, 3.175 mm diameter and 200-300 um thickness; four tungsten probes spaced 0.75 mm; evacuated to ca. few 10^-4 mbar for 24 h; data collected in dark at 25 C using Keithley 4200 SCS.

Temperature
298
Atmosphere
vacuum, ca. few 10^-4 mbar before measurement
Geometry
pressed pellet, finite-dimension correction factors
Context
pristine framework
Measurement source
SI p.S9 · Electrical conductivity measurement · Fig. S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Bulk electrical conductivity of Co-HAB-A100.48 S cm-1Text
Exact Reported
main p.10318 · Results and Discussion · Fig. S6
Bulk electrical conductivity of Co-HAB-A4~0.07 S cm-1 from Fig. S6b; text says Co-HAB-A10 was more than 6 times higherVisual Estimate
Approximate
SI p.S9 · Electrical conductivity measurement · Fig. S6b
Bulk electrical conductivity of Co-HAB-A7~0.26 S cm-1 from Fig. S6bVisual Estimate
Approximate
SI p.S9 · Electrical conductivity measurement · Fig. S6b
Bulk electrical conductivity of Co-HAB-DMarked as a best value within this paper1.57 S cm-1Text
Exact Reported
main p.10318 · Results and Discussion · Fig. 2e,f; Fig. S6
Conductivity measurement temperature25 CText
Exact Reported
SI p.S9 · Electrical conductivity measurement
Conductivity pellet diameter3.175 mm diameterText
Exact Reported
SI p.S9 · Electrical conductivity measurement
Conductivity pellet thickness upper bound200-300 um thicknessText
Range
SI p.S9 · Electrical conductivity measurement
Conductivity pellet thickness lower bound200-300 um thicknessText
Range
SI p.S9 · Electrical conductivity measurement
Four-point probe tip spacing0.75 mm apartText
Exact Reported
SI p.S9 · Electrical conductivity measurement