Porosity — Electrical Conductivity in a Porous, Cubic Rare-Earth Catecholate

Measurement evidence

Porosity

Electrical Conductivity in a Porous, Cubic Rare-Earth Catecholate · Skorupskii G., Dinca M. · Journal of the American Chemical Society · 2020 · 6920-6924

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

N2 adsorption/desorption isotherm and BET fit

Activated Y6HOTP2 nitrogen-sorption powder · Powder

Micromeritics ASAP 2020 Plus; sample activated under dynamic vacuum; N2 isotherm measured in liquid nitrogen bath at 77 K.

Temperature
77
Atmosphere
N2
Context
pristine
Measurement source
SI pp.S6-S7 · Nitrogen adsorption measurements · Fig. S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
BET apparent surface areaMarked as a best value within this paper780 m2/gCaption
Exact Reported
SI p.S7 · Figure S3 caption · Fig. S3
N2 sorption isotherm typeType I adsorption isotherm without appreciable hysteresis on desorptionCaption
Qualitative
SI p.S7 · Figure S3 caption · Fig. S3