Electrical Transport — A coronene-based semiconducting two-dimensional metal-organic framework with ferromagnetic behavior

Measurement evidence

Electrical Transport

A coronene-based semiconducting two-dimensional metal-organic framework with ferromagnetic behavior · Dong R., Zhang Z., Tranca D.C. et al. · Nature Communications · 2018 · 2637

4 measurement groups · 7 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

I-V curves

compressed PTC-Fe pellet · Pellet

Pellet I-V curves measured from -1.0 to +1.0 V.

Atmosphere
vacuum
Geometry
van der Pauw pellet
Context
pristine PTC-Fe pellet
Measurement source
SI p.13 · Supplementary Figures · Supplementary Fig. 13
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
I-V linearityOhmic response between -1.0 and +1.0 VCaption
Qualitative
SI p.13 · Supplementary Figure 13 · Supplementary Fig. 13

variable-temperature conductivity

compressed PTC-Fe pellet · Pellet

Conductivity measured from 20 to 320 K; plotted as sigma(T), ln(sigma) versus 1/T, and ln(sigma) versus T^-1/4.

Temperature
20-320
Atmosphere
vacuum
Geometry
van der Pauw pellet
Context
pristine PTC-Fe pellet
Measurement source
5-6 · DC conductivity measurements · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Arrhenius activation energyEa = 0.2 eV from ln(sigma) versus 1/T0.2 eVText
Rounded Reported
5 · DC conductivity measurements · Fig. 4b
Mott-VRH fit regionln(sigma) versus T^-1/4 over 65-130 K is well fitted to the Mott-VRH modelText
Qualitative
5-6 · DC conductivity measurements · Fig. 4b inset
variable-temperature conductivity rangenon-linear increase of conductivity from 20 to 320 KText
Qualitative
5 · DC conductivity measurements · Fig. 4a

four-probe van der Pauw conductivity

compressed PTC-Fe pellet · Pellet

Bulk compressed pellet; approximately 0.3 mm thick; pressed at approximately 1 GPa; Cu wires/carbon paint contacts; vacuum.

Temperature
300
Atmosphere
vacuum
Geometry
van der Pauw pellet
Context
pristine PTC-Fe pellet
Measurement source
5, 7 · DC conductivity measurements; Conductivity measurements · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
room-temperature pellet conductivityMarked as a best value within this paper~10 S cm-1 at 300 K10 S cm-1Text
Approximate
5 · DC conductivity measurements · Fig. 4a
conductivity batch standard deviationstandard deviation of 1.2 across four batches1.2 S cm-1SD 1.2; four batchesText
Rounded Reported
response p.14 · Reviewer #2 Comment 8 response

vertical two-probe conductivity

compressed PTC-Fe pellet · Pellet

Compressed pellet vertical conductivity measured at room temperature in response to reviewer query.

Temperature
room temperature
Geometry
vertical two-probe pellet
Context
pristine PTC-Fe pellet
Measurement source
response p.14 · Reviewer #2 Comment 9 response
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
vertical pellet conductivity~14 S/cm at room temperature14 S cm-1Text
Approximate
response p.14 · Reviewer #2 Comment 9 response