EDS and ICP-OES elemental analysis
NiFe-MOF/NF ultrathin nanosheet array electrode · Electrode
EDS and ICP-OES reported in SI to cross-check Fe/Ni ratio and formula.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| EDS Fe/Ni atomic ratio | 15% | — | — | Caption Rounded Reported | S10 · Supplementary Figure 8 · Supplementary Fig. 8 |
| EDS-derived formula | Ni0.86Fe0.14(C12H6O4)(H2O)4 | — | — | Caption Rounded Reported | S10 · Supplementary Figure 8 · Supplementary Fig. 8 |
| ICP-OES Fe/Ni atomic ratio | 18% | — | — | Text Rounded Reported | S10 · Supplementary Note 2 |
| ICP-derived formula | Ni0.83Fe0.17(C12H6O4)(H2O)4 | — | — | Text Rounded Reported | S10 · Supplementary Note 2 |