ICP-AES composition analysis
FeNi-DOBDC-3 · Nanosheet
Inductively coupled plasma-atomic emission spectrometry used to quantify Fe and Ni in products.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| FeNi-DOBDC-3 product Fe:Ni atomic ratio | 1:1.171 | — | — | Calculated From Reported Approximate | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-1 Fe content | 8.01 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-2 Fe content | 14.8 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-3 Fe content | 17.17 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-4 Fe content | 20.26 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-1 Ni content | 19.75 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-2 Ni content | 19.53 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-3 Ni content | 21.14 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |
| FeNi-DOBDC-4 Ni content | 10.72 wt% | — | — | SI Table Exact Reported | p012 / S12 · Table S1 · Table S1 |