two-probe pressed-pellet conductivity
pressed Bi-DSBDC-DMA pellet for conductivity · Pellet
0.18 mm pressed pellet between two stainless steel rods in a homemade holder; Keithley 2400 source meter; conductivity measured at different temperatures.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| conductivity at 100 C | approximately 5.8 x 10^-7 S/cm at 100 C from Figure 3d | 0.000058 S/m | — | Figure Axis Approximate | rendered page 3 / article p.2183 · Figure 3d · Figure 3d |
| conductivity at 30 C | approximately 0.2 x 10^-7 S/cm at 30 C from Figure 3d | 0.000002 S/m | — | Figure Axis Approximate | rendered page 3 / article p.2183 · Figure 3d · Figure 3d |
| conductivity at 50 C | approximately 1.1 x 10^-7 S/cm at 50 C from Figure 3d | 0.000011 S/m | — | Figure Axis Approximate | rendered page 3 / article p.2183 · Figure 3d · Figure 3d |
| conductivity at 70 C | approximately 2.5 x 10^-7 S/cm at 70 C from Figure 3d | 0.000025 S/m | — | Figure Axis Approximate | rendered page 3 / article p.2183 · Figure 3d · Figure 3d |
| room-temperature electrical conductivityMarked as a best value within this paper | 2 x 10^-8 S/cm | 0.000002 S/m | — | Text Rounded Reported | rendered pages 1-2 / article pp.2181-2182 · Abstract; Results and discussion · Figure 3d |