Diffraction Structure — Ultrasmall Au(0) Inserted Hollow PCN-222 MOF for the High-Sensitive Detection of Estradiol

Measurement evidence

Diffraction Structure

Ultrasmall Au(0) Inserted Hollow PCN-222 MOF for the High-Sensitive Detection of Estradiol · Biswas S., Chen Y., Xie Y. et al. · Analytical Chemistry · 2020 · 4566-4572

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

powder X-ray diffraction (PXRD)

HPCN-222 activated powder · Powder

PXRD comparison of HPCN-222 and SPCN-222; AuHPCN-222 and AuSPCN-222 in inset.

Geometry
powder
Context
pristine hollow and solid PCN-222 plus Au-loaded analogues
Measurement source
rendered page 3 / article p.4568 · Characterizations · Figure 1a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Au crystallite size from Scherrer peak 10.245 nm0.245 nmText
Exact Reported
rendered page 3 / article p.4568 · Characterizations · Equation 1
Au crystallite size from Scherrer peak 2Marked as a best value within this paper0.187 nm0.187 nmText
Exact Reported
rendered page 3 / article p.4568 · Characterizations · Equation 1
PCN-222 characteristic PXRD peaks4.9, 7.2, 8.37 and 9.79 degrees 2thetaText
Rounded Reported
rendered page 2 / article p.4567 · Characterizations · Figure 1a