Electrical Transport — Three-Dimensional-Coordination Polymer of Zn(II)-Carboxylate: Structural Elucidation, Photoelectrical Conductivity, and Biological Activity

Measurement evidence

Electrical Transport

Three-Dimensional-Coordination Polymer of Zn(II)-Carboxylate: Structural Elucidation, Photoelectrical Conductivity, and Biological Activity · Chandra A., Das M., Pal K. et al. · ACS Omega · 2019 · 17649-17661

6 measurement groups · 27 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

I-V measurement with Ohmic electrode; Keithley sourcemeter

compound 1 thin-film Schottky diode · Thin Film

Conductivity measured from the slope of resultant I-V graph; normal temperature and ambient conditions.

Atmosphere
ambient
Geometry
thin film with Ohmic electrode
Context
pristine framework
Measurement source
17658 · Experimental Section, Schottky Device and I-V Measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivityMarked as a best value within this paper1.37 x 10^-6 S/cm0.000137 S/mText
Exact Reported
17652 · Results and Discussion, I-V Measurement and Analysis

Schottky diode current-voltage and thermionic-emission/Cheung analysis

compound 1 thin-film Schottky diode · Thin Film

ITO/compound 1/Al device; voltage range -1 to +1 V; dark and light conditions; normal temperature and ambient conditions.

Atmosphere
ambient
Geometry
ITO/compound 1/Al Schottky diode, effective diode area 7.065 x 10^-6 m2
Context
pristine framework
Measurement source
17653 · Results and Discussion, I-V Measurement and Analysis · Figure 7; Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Schottky barrier height under dark0.60 eVTable
Exact Reported
17653-17654 · Results and Discussion, I-V Measurement and Analysis · Table 1
Schottky barrier height under lightMarked as a best value within this paper0.58 eVTable
Exact Reported
17654 · Results and Discussion, I-V Measurement and Analysis · Table 1
specific detectivity D*Marked as a best value within this paper2.17 x 10^10 JonesTable
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
ideality factor n under dark3.41Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
ideality factor n under lightMarked as a best value within this paper2.91Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
on/off ratio under dark93Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
on/off ratio under lightMarked as a best value within this paper129Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
photosensitivity SMarked as a best value within this paper20.95Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
responsivity RMarked as a best value within this paper56.21 mA/W0.05621 A/WTable
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
series resistance from dV/dln(I), dark1.37 x 10^6Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
series resistance from dV/dln(I), lightMarked as a best value within this paper6.56 x 10^5Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1

impedance spectroscopy / Nyquist plot

compound 1 thin-film Schottky diode · Thin Film

Frequency 40 Hz to 11 MHz using Agilent 4294A LCR meter; compound 1 and ppmh devices compared.

Geometry
Schottky barrier diode
Context
pristine framework compared with ppmh ligand control
Measurement source
17654 · Results and Discussion, I-V Measurement and Analysis · Figure 10
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Nyquist semicircle diameter for compound 1 deviceMarked as a best value within this paperapproximately 1.2 x 10^5 ohm from Figure 10/S4 x-axis interceptvisual estimate from plotted axisFigure Axis
Approximate
S3 · Supporting Information · Figure S4
Nyquist semicircle diameter for ppmh deviceapproximately 6.2 x 10^5 ohm from Figure 10 x-axis interceptvisual estimate from plotted axisFigure Axis
Approximate
17654 · Results and Discussion, I-V Measurement and Analysis · Figure 10

I-V measurement with Ohmic electrode; Keithley sourcemeter

ppmh ligand thin-film Schottky diode · Thin Film

Conductivity measured from the slope of resultant I-V graph; normal temperature and ambient conditions.

Atmosphere
ambient
Geometry
thin film with Ohmic electrode
Context
ligand control
Measurement source
17652 · Results and Discussion, I-V Measurement and Analysis
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivity6.2 x 10^-7 S/cm0.000062 S/mText
Exact Reported
17652 · Results and Discussion, I-V Measurement and Analysis

Schottky diode current-voltage and thermionic-emission/Cheung analysis

ppmh ligand thin-film Schottky diode · Thin Film

ppmh-based SBD; voltage range -1 to +1 V; dark and light conditions.

Atmosphere
ambient
Geometry
ligand thin-film Schottky diode
Context
ligand control
Measurement source
17653 · Results and Discussion, I-V Measurement and Analysis · Figure 7; Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Schottky barrier height under dark0.65 eVTable
Exact Reported
17654 · Results and Discussion, I-V Measurement and Analysis · Table 1
Schottky barrier height under light0.61 eVTable
Exact Reported
17654 · Results and Discussion, I-V Measurement and Analysis · Table 1
specific detectivity D*4.53 x 10^9 JonesTable
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
ideality factor n under dark4.26Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
ideality factor n under light3.87Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
on/off ratio under dark32Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
on/off ratio under light65Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
photosensitivity S9.98Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
responsivity R5.12 mA/W0.00512 A/WTable
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
series resistance from dV/dln(I), dark7.71 x 10^7Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1
series resistance from dV/dln(I), light7.11 x 10^6Table
Exact Reported
17653 · Results and Discussion, I-V Measurement and Analysis · Table 1

transient photocurrent response

compound 1 thin-film Schottky diode · Thin Film

1.5 G illumination, 100 mW/cm2; light switched on and off at 60 s intervals for 600 s.

Atmosphere
ambient
Geometry
Schottky barrier diode
Context
pristine framework compared with ppmh control
Measurement source
17652-17653 · Results and Discussion, I-V Measurement and Analysis · Figure 8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
transient photocurrent response behavioursteady and reproducible rectangular on-off photoresponse; better response speed for compound 1 than ppmhText
Qualitative
17652 · Results and Discussion, I-V Measurement and Analysis · Figure 8