Co-linear four-point-probe conductivity
Fe(TA)2 thin films doctor-bladed in air · Thin Film
Films made in air and allowed to sit in ambient aerobic conditions for over 1 week; four tungsten carbide probes with 1 mm spacing.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Conductivity of air-made 130 nm Fe(TA)2 film after over 1 week | 4.84 x 10-5 S/cm | — | — | SI Table Exact Reported | 27 · S4 Additional Electrochemical Data · Table S8 |
| Conductivity of air-made 84 nm Fe(TA)2 film after over 1 weekMarked as a best value within this paper | 1.53 x 10-4 S/cm | — | — | SI Table Exact Reported | 27 · S4 Additional Electrochemical Data · Table S8 |
| Conductivity of air-made 84 nm Fe(TA)2 carbon/PVDF composite film after over 1 weekMarked as a best value within this paper | 6.30 x 10-4 S/cm | — | — | SI Table Exact Reported | 27 · S4 Additional Electrochemical Data · Table S8 |
| Conductivity of air-made bulk Fe(TA)2 film after over 1 week | 1.08 x 10-5 S/cm | — | — | SI Table Exact Reported | 27 · S4 Additional Electrochemical Data · Table S8 |