Spectroscopy — Shielding against Unfolding by Embedding Enzymes in Metal-Organic Frameworks via a de Novo Approach

Measurement evidence

Spectroscopy

Shielding against Unfolding by Embedding Enzymes in Metal-Organic Frameworks via a de Novo Approach · Liao F.-S., Lo W.-S., Hsu Y.-S. et al. · Journal of the American Chemical Society · 2017 · 6530-6533

3 measurement groups · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Fluorescence emission spectroscopy

CAT@ZIF-8 · Powder

CAT@ZIF-8 fluorescence after exposure to 6 M urea, 8 M urea, 0.1 M 3-AT, 80 deg C and 80% DMF.

Context
ZIF-8 enzyme-in-MOF composite used to avoid ZIF-90 fluorescence interference
Measurement source
3 · Fluorescence spectroscopy · Figure 3b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
lambda_max, native CAT@ZIF-8337 nmText
Exact Reported
3 · Fluorescence spectroscopy · Figure 3
lambda_max shift under ureasignificantly lower degree of shift than free CAT after 6 and 8 M ureaText
Qualitative
3 · Fluorescence spectroscopy · Figure 3b

Fluorescence emission spectroscopy

Free CAT · Unknown

Free CAT fluorescence after exposure to 6 M urea, 8 M urea and 0.1 M 3-AT; lambda_max used as unfolding indicator.

Context
Free enzyme control
Measurement source
3 · Fluorescence spectroscopy · Figure 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
lambda_max after 6 M urea343 nmText
Exact Reported
3 · Fluorescence spectroscopy · Figure 3a
lambda_max after 8 M urea348 nmText
Exact Reported
3 · Fluorescence spectroscopy · Figure 3a
lambda_max, native free CAT337 nmText
Exact Reported
3 · Fluorescence spectroscopy · Figure 3

SDS-PAGE

CAT@ZIF-90 · Powder

CAT@ZIF-90 dissolved in 0.2 M HCl, mixed with loading buffer, heated at 95 deg C for 5 min, run on 4% stacking/12% resolving gel at 20 mA.

Context
Encapsulated CAT compared to free CAT and CAT-on-ZIF-90
Measurement source
S13 · SDS-PAGE analysis · Figure S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource