Optical pump terahertz probe (OPTP) time-resolved photoconductivity
M-THQ mylar tape cell series · Powder
400 nm optical pump at 1 kHz, 110 mW; powdered M-THQ in 3 um mylar tape cell; Gaussian-convoluted single-exponential fit with long-time offset.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Fe-THQ THz attenuation loss after two weeks in N2 | ~1% decrease in maximum THz attenuation after two weeks in 99% N2 at 140 mW, 400 nm | — | ~ | Text Approximate | 12 · Fe-THQ oxidation · Figure S8 |
| Cu-THQ OPTP fit A1 | 0.0259 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Cu-THQ previously reported photoconductivity comparison | 0.2 S/m from previous report | — | — | Text Exact Reported | 11 · OPTP spectroscopy |
| Cu-THQ OPTP fit tau1 | 0.426 ps | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Cu-THQ OPTP long-time offset y0 | 0.00147 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Fe-THQ OPTP fit A1Marked as a best value within this paper | 0.0667 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Fe-THQ long-lived THz componentMarked as a best value within this paper | -0.2% THz, about one third of total signal | — | — | Text Rounded Reported | 11 · OPTP spectroscopy · Figure 4a |
| Fe-THQ photoconductivity after 2 ps pump delayMarked as a best value within this paper | 7.7 S/m | — | — | Text Exact Reported | 11 · OPTP spectroscopy · Figure 4b |
| Fe-THQ photoconductivity after 3.5 ps pump delay | 6.1 S/m | — | — | Text Exact Reported | 11 · OPTP spectroscopy · Figure 4c |
| Fe-THQ OPTP fit t0 | 0.378 ps | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Fe-THQ OPTP fit tau1 | 0.381 ps | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Fe-THQ OPTP long-time offset y0Marked as a best value within this paper | 0.00955 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Ni-THQ OPTP fit A1 | 0.0409 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Ni-THQ OPTP fit tau1 | 0.215 ps | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Ni-THQ OPTP long-time offset y0 | 0.0000748 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Ni-THQ and Zn-THQ photo-induced THz difference signal threshold | less than 0.01% | — | < | Text Range | 10 · OPTP spectroscopy · Figure 4a |
| Zn-THQ OPTP fit A1 | 0.00474 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Zn-THQ OPTP fit tau1 | 2.25 ps | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |
| Zn-THQ OPTP long-time offset y0 | 0.000954 | — | — | SI Table Exact Reported | 10 · Table S4 · Table S4 |