Electrical Transport — Engineering Band Gap and Photoconduction in Semiconducting Metal Organic Frameworks: Metal Node Effect

Measurement evidence

Electrical Transport

Engineering Band Gap and Photoconduction in Semiconducting Metal Organic Frameworks: Metal Node Effect · Nyakuchena J., Ostresh S., Neu J. et al. · Journal of Physical Chemistry Letters · 2023 · 5960-5965

1 measurement group · 19 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Optical pump terahertz probe (OPTP) time-resolved photoconductivity

M-THQ mylar tape cell series · Powder

400 nm optical pump at 1 kHz, 110 mW; powdered M-THQ in 3 um mylar tape cell; Gaussian-convoluted single-exponential fit with long-time offset.

Geometry
3 um mylar tape cell powder sample
Context
pristine MOF powders in nonconductive tape cell
Measurement source
10 · OPTP spectroscopy · Figure 4 and Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Fe-THQ THz attenuation loss after two weeks in N2~1% decrease in maximum THz attenuation after two weeks in 99% N2 at 140 mW, 400 nm~Text
Approximate
12 · Fe-THQ oxidation · Figure S8
Cu-THQ OPTP fit A10.0259SI Table
Exact Reported
10 · Table S4 · Table S4
Cu-THQ previously reported photoconductivity comparison0.2 S/m from previous reportText
Exact Reported
11 · OPTP spectroscopy
Cu-THQ OPTP fit tau10.426 psSI Table
Exact Reported
10 · Table S4 · Table S4
Cu-THQ OPTP long-time offset y00.00147SI Table
Exact Reported
10 · Table S4 · Table S4
Fe-THQ OPTP fit A1Marked as a best value within this paper0.0667SI Table
Exact Reported
10 · Table S4 · Table S4
Fe-THQ long-lived THz componentMarked as a best value within this paper-0.2% THz, about one third of total signalText
Rounded Reported
11 · OPTP spectroscopy · Figure 4a
Fe-THQ photoconductivity after 2 ps pump delayMarked as a best value within this paper7.7 S/mText
Exact Reported
11 · OPTP spectroscopy · Figure 4b
Fe-THQ photoconductivity after 3.5 ps pump delay6.1 S/mText
Exact Reported
11 · OPTP spectroscopy · Figure 4c
Fe-THQ OPTP fit t00.378 psSI Table
Exact Reported
10 · Table S4 · Table S4
Fe-THQ OPTP fit tau10.381 psSI Table
Exact Reported
10 · Table S4 · Table S4
Fe-THQ OPTP long-time offset y0Marked as a best value within this paper0.00955SI Table
Exact Reported
10 · Table S4 · Table S4
Ni-THQ OPTP fit A10.0409SI Table
Exact Reported
10 · Table S4 · Table S4
Ni-THQ OPTP fit tau10.215 psSI Table
Exact Reported
10 · Table S4 · Table S4
Ni-THQ OPTP long-time offset y00.0000748SI Table
Exact Reported
10 · Table S4 · Table S4
Ni-THQ and Zn-THQ photo-induced THz difference signal thresholdless than 0.01%<Text
Range
10 · OPTP spectroscopy · Figure 4a
Zn-THQ OPTP fit A10.00474SI Table
Exact Reported
10 · Table S4 · Table S4
Zn-THQ OPTP fit tau12.25 psSI Table
Exact Reported
10 · Table S4 · Table S4
Zn-THQ OPTP long-time offset y00.000954SI Table