Other — Turning 2D MOFs into Mixed Ionic-Electronic Conductors via Side Chain Engineering

Measurement evidence

Other

Turning 2D MOFs into Mixed Ionic-Electronic Conductors via Side Chain Engineering · Roh H., Su A.Y., Oh C. et al. · Journal of the American Chemical Society · 2025 · 38419-38427

6 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

dynamic light scattering

Ni-1EG pristine powder · Powder

cluster sizes in acetone and water

Context
pristine Ni-MOF dispersion
Measurement source
p006 · Results and Discussion · Figure S33
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DLS cluster size in acetoneMarked as a best value within this paper~20 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS larger cluster size in water~200 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS small cluster size in waterMarked as a best value within this paper~3.5 nmText
Approximate
p006 · Results and Discussion · Figure S33

dynamic light scattering

Ni-2EG pristine powder · Powder

cluster sizes in acetone and water

Context
pristine Ni-MOF dispersion
Measurement source
p006 · Results and Discussion · Figure S33
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DLS cluster size in acetone~150 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS larger cluster size in water~600 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS small cluster size in water~20 nmText
Approximate
p006 · Results and Discussion · Figure S33

dynamic light scattering

Ni-nBu pristine powder · Powder

cluster sizes in acetone and water

Context
pristine Ni-MOF dispersion
Measurement source
p006 · Results and Discussion · Figure S33
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DLS cluster size in acetone~420 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS larger cluster size in water~1000 nmText
Approximate
p006 · Results and Discussion · Figure S33
DLS small cluster size in water~250 nmText
Approximate
p006 · Results and Discussion · Figure S33

ICP-MS lithium uptake quantification

LiTFSI-Ni-1EG · Powder

Li/Ni molar ratio after 3 days in 1 M LiTFSI/PC

Temperature
room temperature
Context
guest-loaded Ni-MOF
Measurement source
p004 · Results and Discussion · Figure 3c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Li/Ni molar ratio after LiTFSI soakingMarked as a best value within this paper0.12069Text
Exact Reported
p004 · Results and Discussion · Figure 3c

ICP-MS lithium uptake quantification

LiTFSI-Ni-2EG · Powder

Li/Ni molar ratio after 3 days in 1 M LiTFSI/PC

Temperature
room temperature
Context
guest-loaded Ni-MOF
Measurement source
p004 · Results and Discussion · Figure 3c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Li/Ni molar ratio after LiTFSI soaking0.04978Text
Exact Reported
p004 · Results and Discussion · Figure 3c

ICP-MS lithium uptake quantification

LiTFSI-Ni-nBu · Powder

Li/Ni molar ratio after 3 days in 1 M LiTFSI/PC

Temperature
room temperature
Context
guest-loaded Ni-MOF
Measurement source
p004 · Results and Discussion · Figure 3c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Li/Ni molar ratio after LiTFSI soaking0.10679Text
Exact Reported
p004 · Results and Discussion · Figure 3c