Spectroscopy — Hydrolytically Stable Luminescent Cationic Metal Organic Framework for Highly Sensitive and Selective Sensing of Chromate Anions in Natural Water Systems

Measurement evidence

Spectroscopy

Hydrolytically Stable Luminescent Cationic Metal Organic Framework for Highly Sensitive and Selective Sensing of Chromate Anions in Natural Water Systems · Liu W., Wang Y., Bai Z. et al. · ACS Applied Materials and Interfaces · 2017 · 16448-16457

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Photoluminescence spectroscopy and UV-vis absorption spectroscopy

finely ground powder of 1 · Powder

Excitation at 280 nm; Eu3+ emissions monitored at 592, 616, 653 and 696 nm. UV-vis absorption spectra of 1 and Cr(VI) compared.

Atmosphere
aqueous suspensions/solutions
Context
pristine framework sensing baseline
Measurement source
p004 / article p.16451 · Results and Discussion - Sensing Property · Figure 3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cr(VI) absorption overlap wavelengthCr(VI) absorption at 280 nm partially overlaps absorption peak of 1Text
Exact Reported
p004 / article p.16451 · Results and Discussion - Sensing Property · Figure 3
Eu3+ characteristic emission wavelengths592, 616, 653, and 696 nmText
Exact Reported
p004 / article p.16451 · Results and Discussion - Sensing Property · Figure 3