Electrochemistry Application — Metal-Organic Framework-Based Tribovoltaic Textile for Human Body Signal Monitoring

Measurement evidence

Electrochemistry Application

Metal-Organic Framework-Based Tribovoltaic Textile for Human Body Signal Monitoring · Li Y., Wu Y., Shokurov A.V. et al. · Advanced Science · 2025 · 2414086

1 measurement group · 4 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Capacitor charging by single or series-connected Cu-BHT TVTs

Cu-BHT TVT · Electrode

1 uF and 4.7 uF capacitors charged at 2 Hz or 4 Hz; six TVT devices connected in series for calculator demonstration

Geometry
single TVT and six TVTs in series
Context
energy-harvesting application
Measurement source
p005-p007 · Results and Discussion · Figure 4b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
1 uF capacitor charging at 2 Hzcharged to approximately 0.5 V in 60 s at 2 HzText
Approximate
p005 · Results and Discussion · Figure 4b
1 uF capacitor charging at 4 HzMarked as a best value within this papercharged to approximately 0.55 V in 30 s at 4 HzText
Approximate
p005 · Results and Discussion · Figure 4b
4.7 uF capacitor charging at 4 Hz4.7 uF capacitor charged to approximately 0.4 V in 150 s at 4 HzText
Approximate
p005 · Results and Discussion · Figure 4b
Series TVTs capacitor voltage for calculator demonstrationMarked as a best value within this papersix TVT devices in series charged a 1 uF capacitor to 1.6 VText
Exact Reported