Other — Defect Engineering to Tailor Metal Vacancies in 2D Conductive Metal-Organic Frameworks: An Example in Electrochemical Sensing

Measurement evidence

Other

Defect Engineering to Tailor Metal Vacancies in 2D Conductive Metal-Organic Frameworks: An Example in Electrochemical Sensing · Luo Y., Wu Y., Braun A. et al. · ACS Nano · 2022 · 20820-20830

3 measurement groups · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

ICP-MS for Ag and elemental analyser for S and C

Ag-BHT film prepared at pH 2 · Thin Film

Elemental concentrations for Ag-BHT films prepared at pH 2, 1, and 0.

Geometry
thin films dissolved/analysed
Context
pristine framework pH series
Measurement source
30 · 2.3 Supplemental Data · Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ag-BHT pH 0 Ag contentAg 61.2 wt%SI Table
Exact Reported
30 · 2.3 Supplemental Data · Table S3
Ag-BHT pH 2 Ag contentAg 43.7 wt%SI Table
Exact Reported
30 · 2.3 Supplemental Data · Table S3

ICP-MS for Cu and elemental analyser for S and C

Cu-BHT film prepared at pH 2 · Thin Film

Elemental concentrations for Cu-BHT films prepared at pH 2, 1, and 0.

Geometry
thin films dissolved/analysed
Context
pristine framework pH series
Measurement source
20 · 2.3 Supplemental Data · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu-BHT pH 0 Cu contentCu 41.1 wt%SI Table
Exact Reported
20 · 2.3 Supplemental Data · Table S1
Cu-BHT pH 1 Cu contentCu 36.9 wt%SI Table
Exact Reported
20 · 2.3 Supplemental Data · Table S1
Cu-BHT pH 2 C contentC 20.4 wt%SI Table
Exact Reported
20 · 2.3 Supplemental Data · Table S1
Cu-BHT pH 2 Cu contentCu 26.8 wt%SI Table
Exact Reported
20 · 2.3 Supplemental Data · Table S1
Cu-BHT pH 2 S contentS 52.8 wt%SI Table
Exact Reported
20 · 2.3 Supplemental Data · Table S1

ICP-MS for Ni and elemental analyser for S and C/Na

Ni-BHT film prepared at pH 2 · Thin Film

Elemental concentrations for Ni-BHT films prepared at pH 2, 1, and 0.

Geometry
thin films dissolved/analysed
Context
pristine framework pH series
Measurement source
29 · 2.3 Supplemental Data · Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni-BHT pH 0 Ni contentNi 24.6 wt%SI Table
Exact Reported
29 · 2.3 Supplemental Data · Table S2
Ni-BHT pH 2 Ni contentNi 20.8 wt%SI Table
Exact Reported
29 · 2.3 Supplemental Data · Table S2