Electrical Transport — Highly Polarizable Triiodide Anions (I3-) as Cross-Linkers for Coordination Polymers: Closing the Semiconductive Band Gap

Measurement evidence

Electrical Transport

Highly Polarizable Triiodide Anions (I3-) as Cross-Linkers for Coordination Polymers: Closing the Semiconductive Band Gap · He J., Cao P., Wu C. et al. · Inorganic Chemistry · 2015 · 6087-6089

2 measurement groups · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Two-probe I-V measurement using Keithley 4200 SCS semiconductor parameter analyser

black needle-like single crystals of compound 1 · Single Crystal

Needle-like single crystals measured in a two-probe station; Figure S6 shows I-A curve and probe configuration photographs.

Temperature
room temperature
Geometry
two-probe configuration on needle-like single crystal
Context
pristine target sample
Measurement source
p002 / article p.6088 · Electrical conductivity · Figure S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
two-probe electrical conductivity of compound 1Marked as a best value within this paper9.38 x 10^-4 S m^-10.000938 S/mText
Exact Reported
p002 / article p.6088 · Electrical conductivity · Figure S6
two-probe I-V behaviourtypical ohmic contactText
Qualitative
p002 / article p.6088 · Electrical conductivity · Figure S6

Conductivity comparison reported for TCuI

TCuI comparison sample · Unknown

Sample geometry and measurement details not specified in this paper; value used as comparison to compound 1.

Context
pristine comparison/control
Measurement source
p002 / article p.6088 · Electrical conductivity comparison
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivity upper bound of TCuI controllower than 10^-10 S m^-11e-10 S/mText
Range
p002 / article p.6088 · Electrical conductivity comparison