Diffraction Structure — Three-dimensional Co/Ni bimetallic organic frameworks for high-efficient catalytic ozonation of atrazine: Mechanism, effect parameters, and degradation pathways analysis

Measurement evidence

Diffraction Structure

Three-dimensional Co/Ni bimetallic organic frameworks for high-efficient catalytic ozonation of atrazine: Mechanism, effect parameters, and degradation pathways analysis · Ye G., Luo P., Zhao Y. et al. · Chemosphere · 2020 · 126767

3 measurement groups · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Powder X-ray diffraction with Cu Ka radiation

Co-MOF red crystals · Powder

D8-Advance diffractometer; 40 kV, 40 mA; 2theta range 5-90 deg.

Context
single-metal pristine control
Measurement source
2-3 · 2.3 Catalyst characterization; 3.1 Characterization of catalysts · Fig. S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-MOF XRD peak17 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Co-MOF XRD peak18 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Co-MOF XRD peak27 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2

Powder X-ray diffraction with Cu Ka radiation

Co/Ni-MOF brown powder · Powder

D8-Advance diffractometer; 40 kV, 40 mA; 2theta range 5-90 deg.

Context
target bimetallic sample
Measurement source
2-3 · 2.3 Catalyst characterization; 3.1 Characterization of catalysts · Fig. S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co/Ni-MOF XRD peak10 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Co/Ni-MOF XRD peak17 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Co/Ni-MOF XRD peak27 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2

Powder X-ray diffraction with Cu Ka radiation

Ni-MOF green crystals · Powder

D8-Advance diffractometer; 40 kV, 40 mA; 2theta range 5-90 deg.

Context
single-metal pristine control
Measurement source
2-3 · 2.3 Catalyst characterization; 3.1 Characterization of catalysts · Fig. S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni-MOF XRD peak10 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Ni-MOF XRD peak16 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2
Ni-MOF XRD peak17 deg 2thetaText
Rounded Reported
3 · 3.1 Characterization of catalysts · Fig. S2