Optical pump terahertz probe spectroscopy (OPTP)
Cu-PTT nanosheet powder · Nanosheet
Powder sample in 3 um mylar tape cell; 400 nm optical excitation with 150 uJ pulse followed by time-delayed THz pulse; peak THz transmission versus delay time measured.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| OPTP fitted A1 | -0.1417% | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| OPTP fitted A2 | -0.02305% | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| OPTP fitted IRF | 0.3716 ps | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| Short-lived THz attenuationMarked as a best value within this paper | ~0.07% | — | ~ | Text Approximate | 10 · Results and Discussion · Figure 3a |
| OPTP fast decay tau1Marked as a best value within this paper | 0.08285 ps | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| OPTP longer decay tau2Marked as a best value within this paper | 1.528 ps | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| OPTP long-time offset y0Marked as a best value within this paper | -0.003595% | — | — | SI Table Exact Reported | S13 · Supporting Information · Table S1 |
| Rounded long-lived offset from main text | 0.004% | — | — | Text Rounded Reported | 11 · Results and Discussion |
| Long-lived offset fraction of total photoconductivity | more than 10% of the total photoconductivity | — | more than | Text Approximate | 11 · Results and Discussion |