Spectroscopy — In-Built Fabrication of MOF Assimilated Porous Hollow Carbon from Pre-Hydrolysate for Supercapacitor

Measurement evidence

Spectroscopy

In-Built Fabrication of MOF Assimilated Porous Hollow Carbon from Pre-Hydrolysate for Supercapacitor · Zhao X., Li C., Sha L. et al. · Polymers · 2022 · 3377

4 measurement groups · 8 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Raman spectroscopy

C1-ZIF-67 powder · Powder

Renishaw inVia Raman, He-Ne laser source lambda = 532 nm.

Context
one-step composite
Measurement source
p003-p007 / article pp.3-7 · 2.2 Characterization; 3 Results and Discussion · Figure 4b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
D band position1350 cm-1Text
Rounded Reported
p007 / article p.7 · 3 Results and Discussion · Figure 4b
G band position1590 cm-1Text
Rounded Reported
p007 / article p.7 · 3 Results and Discussion · Figure 4b
ID/IG ratio1 by calculation1 dimensionlessText
Rounded Reported
p007 / article p.7 · 3 Results and Discussion · Figure 4b

Raman spectroscopy

C2-ZIF-67 powder · Powder

Renishaw inVia Raman, He-Ne laser source lambda = 532 nm.

Context
two-step target composite
Measurement source
p007 / article p.7 · 3 Results and Discussion · Figure 4b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ID/IG ratio1 by calculation1 dimensionlessText
Rounded Reported
p007 / article p.7 · 3 Results and Discussion · Figure 4b

X-ray photoelectron spectroscopy (XPS)

C1-ZIF-67 powder · Powder

Escalab 250Xi with Al Kalpha X-ray source.

Context
one-step composite
Measurement source
p003-p008 / article pp.3-8 · 2.2 Characterization; 3 Results and Discussion · Figure 5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co 2p1/2 peak as reported780 eVText
Exact Reported
p007 / article p.7 · 3 Results and Discussion · Figure 5b
Co 2p3/2 peak as reported795.8 eVText
Exact Reported
p007 / article p.7 · 3 Results and Discussion · Figure 5b
Co3O4 peak as reported803.5 eVText
Exact Reported
p007 / article p.7 · 3 Results and Discussion · Figure 5b

X-ray photoelectron spectroscopy (XPS)

C2-ZIF-67 powder · Powder

Escalab 250Xi with Al Kalpha X-ray source.

Context
two-step target composite
Measurement source
p007-p008 / article pp.7-8 · 3 Results and Discussion · Figure 5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Metallic Co peakMarked as a best value within this paper777.5 eVText
Exact Reported
p007 / article p.7 · 3 Results and Discussion · Figure 5b