Electrical Transport — Structure, Conductivity, and Magnetic Properties of (Phthalocyaninato)nickel(II) Bromide

Measurement evidence

Electrical Transport

Structure, Conductivity, and Magnetic Properties of (Phthalocyaninato)nickel(II) Bromide · Palmer S.M., Stanton J.L., Hoffman B.M. et al. · Inorganic Chemistry · 1986 · 2296-2300

1 measurement group · 11 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Four-probe low-frequency ac conductivity measurement

single crystals of Ni(pc)Br · Single Crystal

Conductivity measured along the needle axis (c axis, stacking direction); low temperatures obtained with cold N2 gas from liquid N2 boiloff.

Temperature
ca. 300 to above 100 K
Atmosphere
cold N2 gas for low-temperature measurements
Geometry
Crystals mounted in integrated circuit cans on 8-micron graphite fibres; palladium paste electrical contacts.
Context
pristine Ni(pc)Br single crystal
Measurement source
2297 · Experimental Section - Single-Crystal Electrical Conductivity Studies · Figure 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
absolute conductivity uncertaintyDelta sigma/sigma = +/-0.4Text
Exact Reported
2297 · Experimental Section - Single-Crystal Electrical Conductivity Studies
figure-read c-axis conductivity near 125 Kca. 245 ohm^-1 cm^-1 at 125 K from Figure 2245 S cm^-1visual estimate from plotted axisFigure Axis
Approximate
2298 · Results - Conductivity Measurements · Figure 2
figure-read c-axis conductivity near 200 Kca. 200 ohm^-1 cm^-1 at 200 K from Figure 2200 S cm^-1visual estimate from plotted axisFigure Axis
Approximate
2298 · Results - Conductivity Measurements · Figure 2
figure-read c-axis conductivity near 300 Kca. 125 ohm^-1 cm^-1 at 300 K from Figure 2125 S cm^-1visual estimate from plotted axisFigure Axis
Approximate
2298 · Results - Conductivity Measurements · Figure 2
conductivity fit gamma lower boundgamma = 1.45-1.5 for 200 < T < 300 KrangeText
Range
2298 · Results - Conductivity Measurements · Equation 1
conductivity fit gamma upper boundgamma = 1.45-1.5 for 200 < T < 300 KrangeText
Range
2298 · Results - Conductivity Measurements · Equation 1
irreversible conductivity loss thresholdbelow about 100 KaboutText
Approximate
2298 · Results - Conductivity Measurements · Figure 2
relative conductivity accuracy+/-1%0.01 fractionText
Exact Reported
2297 · Experimental Section - Single-Crystal Electrical Conductivity Studies
conductivity increase on cooling to 180-200 Kabout 1.8 times that at room temperatureText
Approximate
2298 · Results - Conductivity Measurements · Figure 2
room-temperature c-axis conductivity lower end125 to 200 ohm^-1 cm^-1125 S cm^-1absolute conductivity Delta sigma/sigma = +/-0.4Text
Range
2298 · Results - Conductivity Measurements · Figure 2
room-temperature c-axis conductivity upper endMarked as a best value within this paper125 to 200 ohm^-1 cm^-1200 S cm^-1absolute conductivity Delta sigma/sigma = +/-0.4Text
Range
2298 · Results - Conductivity Measurements · Figure 2