Four-probe low-frequency ac conductivity measurement
single crystals of Ni(pc)Br · Single Crystal
Conductivity measured along the needle axis (c axis, stacking direction); low temperatures obtained with cold N2 gas from liquid N2 boiloff.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| absolute conductivity uncertainty | Delta sigma/sigma = +/-0.4 | — | — | Text Exact Reported | 2297 · Experimental Section - Single-Crystal Electrical Conductivity Studies |
| figure-read c-axis conductivity near 125 K | ca. 245 ohm^-1 cm^-1 at 125 K from Figure 2 | 245 S cm^-1 | visual estimate from plotted axis | Figure Axis Approximate | 2298 · Results - Conductivity Measurements · Figure 2 |
| figure-read c-axis conductivity near 200 K | ca. 200 ohm^-1 cm^-1 at 200 K from Figure 2 | 200 S cm^-1 | visual estimate from plotted axis | Figure Axis Approximate | 2298 · Results - Conductivity Measurements · Figure 2 |
| figure-read c-axis conductivity near 300 K | ca. 125 ohm^-1 cm^-1 at 300 K from Figure 2 | 125 S cm^-1 | visual estimate from plotted axis | Figure Axis Approximate | 2298 · Results - Conductivity Measurements · Figure 2 |
| conductivity fit gamma lower bound | gamma = 1.45-1.5 for 200 < T < 300 K | — | range | Text Range | 2298 · Results - Conductivity Measurements · Equation 1 |
| conductivity fit gamma upper bound | gamma = 1.45-1.5 for 200 < T < 300 K | — | range | Text Range | 2298 · Results - Conductivity Measurements · Equation 1 |
| irreversible conductivity loss threshold | below about 100 K | — | about | Text Approximate | 2298 · Results - Conductivity Measurements · Figure 2 |
| relative conductivity accuracy | +/-1% | 0.01 fraction | — | Text Exact Reported | 2297 · Experimental Section - Single-Crystal Electrical Conductivity Studies |
| conductivity increase on cooling to 180-200 K | about 1.8 times that at room temperature | — | — | Text Approximate | 2298 · Results - Conductivity Measurements · Figure 2 |
| room-temperature c-axis conductivity lower end | 125 to 200 ohm^-1 cm^-1 | 125 S cm^-1 | absolute conductivity Delta sigma/sigma = +/-0.4 | Text Range | 2298 · Results - Conductivity Measurements · Figure 2 |
| room-temperature c-axis conductivity upper endMarked as a best value within this paper | 125 to 200 ohm^-1 cm^-1 | 200 S cm^-1 | absolute conductivity Delta sigma/sigma = +/-0.4 | Text Range | 2298 · Results - Conductivity Measurements · Figure 2 |