Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Colourimetric H2S sensing by optical photographs

BFMOF-1 H2S aqueous sensing series · Single Crystal

BFMOF-1 crystallites stirred/heated for 0.5 h at 80 C in aqueous H2S/NaSH solutions.

Temperature
353
Atmosphere
aqueous H2S/NaSH
Geometry
15 mL vials, 10 mL analyte solution
Context
pristine framework used as disposable H2S sensor
Measurement source
main p.4, article p.14441 · H2S sensing · Figure 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H2S sensing colour concentration352 microm (12 ppm)352 micromol/LText
Exact Reported
main p.4, article p.14441 · H2S sensing · Figure 4
H2S sensing colour concentration35.2 microm (1.2 ppm)35.2 micromol/LText
Exact Reported
main p.4, article p.14441 · H2S sensing · Figure 4
H2S sensing colour concentration88 microm (3.0 ppm)88 micromol/LText
Exact Reported
main p.4, article p.14441 · H2S sensing · Figure 4
Highest Figure 4 H2S concentration60 ppmCaption
Exact Reported
main p.4, article p.14441 · Figure caption · Figure 4
Lowest reported visually distinct H2S responseMarked as a best value within this paper17.6 microm (0.60 ppm)17.6 micromol/LText
Exact Reported
main p.4, article p.14441 · H2S sensing · Figure 4