Thermogravimetric analysis (TGA)
PCN-222(Fe) · Powder
TGA thermal stability of PCN-222(Fe, Co, Ni, and Cu) using Mettler Toledo TGA/DSC at 10 C/min in air; curves in SI Figure S4.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| First TGA weight-loss stage threshold | first weight loss occurs below 160 C due to removal of entrapped guest solvent | — | below | Text Approximate | 3 · Characterization of catalyst · Figure S4 |
| Thermal stability with negligible weight loss up to 300 C | negligible weight loss is observed up to 300 C | — | up to | Text Approximate | 3 · Characterization of catalyst · Figure S4 |
| TGA residue for PCN-222(Co) | 26% | — | — | Text Rounded Reported | 3 · Characterization of catalyst · Figure S4 |
| TGA residue for PCN-222(Cu) | 30% | — | — | Text Rounded Reported | 3 · Characterization of catalyst · Figure S4 |
| TGA residue for PCN-222(Fe) | 28% | — | — | Text Rounded Reported | 3 · Characterization of catalyst · Figure S4 |
| TGA residue for PCN-222(Ni) | 27% | — | — | Text Rounded Reported | 3 · Characterization of catalyst · Figure S4 |