Impedance spectroscopy, Zahner ZENNIUM potentiostatic mode
Pressed TUB40 pellet · Pellet
20 mV amplitude, 100 mHz to 100 kHz; pellet under 1 MPa load; resistance calculated from mean |Z| between 0.1 and 200 Hz where phase was below 1 degree.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Pellet electrical conductivity | 142 S m-1 | 142 S m-1 | — | Calculated From Reported Exact Reported | main p.3, article p.3 · Pellet-Based Conductivity · Equation 1 |
| Pellet impedance magnitude | |Z| = 179.3 +/- 0.2 mOhm between 0.1 and about 500 Hz | 0.1793 Ohm | +/- 0.2 mOhm | Caption Exact Reported | main p.3, article p.3 · Pellet-Based Conductivity · Figure 2b |
| Low-frequency phase shift | 0 degrees | 0 degree | — | Text Exact Reported | main p.3, article p.3 · Pellet-Based Conductivity · Figure 2b |