WNMC400 motion controller and Keithley 2450 source meter at 1 V
Co-PCCF-1000 · Thin Film
Relative resistance change under tensile strain, strain-rate tests, and cyclic stability.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| gauge factor in 3-30% strain regionMarked as a best value within this paper | 203 | — | — | Text Exact Reported | 13 (11837) · 3.7 Sensing Property · Figure 11e |
| gauge factor in 0.05-3% strain region | 25.6 | — | — | Text Exact Reported | 13 (11837) · 3.7 Sensing Property · Figure 11e |
| human motion detection demonstrations | belly breathing, pulse, wrist, elbow, knee, and ankle | — | — | Text Qualitative | 13 (11837) · 3.7 Sensing Property · Figure 12 |
| strain-sensing cyclic stability | more than 200 continuous cycles at 6% strain | — | lower bound | Text Approximate | 13 (11837) · 3.7 Sensing Property · Figure 11f |
| minimum strain detection limitMarked as a best value within this paper | 0.05 percent | — | — | Text Exact Reported | 13 (11837) · 3.7 Sensing Property · Figure 11a-c |
| strain detection rangeMarked as a best value within this paper | 0.05-30% | — | range | Text Range | 13 (11837) · 3.7 Sensing Property · Figure 11e |