X-ray diffraction using Bruker D8 Advance with Lynxeye detector in theta-2theta geometry and Cu Kalpha radiation
conventional low-quality HKUST-1 SURMOF · Thin Film
HKUST-1 SURMOFs grown on quartz glass; black curve is low-quality sample, red curve is high-quality sample, grey curve is calculated HKUST-1 powder diffractogram.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| HKUST-1 structure verification by XRDMarked as a best value within this paper | X-ray diffraction verifies crystalline HKUST-1 MOF structure | — | — | Caption Qualitative | S-2 · Supporting Information 1 · Figure S1 |
| XRD radiation wavelength | CuKalpha radiation, lambda = 0.154 nm | — | — | Caption Exact Reported | S-2 · Supporting Information 1 · Figure S1 |