Spectroscopy — Rational design of sulfur vacancy-rich NiCo2S4/C nanostructure for high-performance hybrid supercapacitors

Measurement evidence

Spectroscopy

Rational design of sulfur vacancy-rich NiCo2S4/C nanostructure for high-performance hybrid supercapacitors · Tian J., Guo H., Wang M. et al. · Journal of Alloys and Compounds · 2024 · 173949

4 measurement groups · 27 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

FT-IR spectroscopy

NCSC · Powder

FT-IR spectra of Na-BTC, Ni1Co1-BTC, NCO, NCS and NCSC.

Context
precursor and derived materials
Measurement source
8 · 3.1 · Fig. 4f
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FTIR S-M asymmetric stretching peak1035 cm-1Text
Exact Reported
8 · 3.1 · Fig. 4f
FTIR S-M symmetric stretching peak613 cm-1Text
Exact Reported
8 · 3.1 · Fig. 4f

ICP-OES and elemental analysis

NCSC · Powder

Metal contents by ICP-OES; carbon content by elemental analyser.

Context
target composite and NCS control
Measurement source
2 · Supporting information · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ICP response value for Co in NCS30,583SI Table
Exact Reported
2 · Supporting information · Table S1
Co content in NCS46.5 wt%Text
Exact Reported
8 · 3.1 · Table S1 referenced
ICP response value for Ni in NCS33,898SI Table
Exact Reported
2 · Supporting information · Table S1
Ni content in NCS38.2 wt%Text
Exact Reported
8 · 3.1 · Table S1 referenced
carbon content in NCSC10 wt%Text
Rounded Reported
8 · 3.1
ICP response value for Co in NCSC20,099SI Table
Exact Reported
2 · Supporting information · Table S1
Co content in NCSC26.7 wt%Text
Exact Reported
8 · 3.1 · Table S1 referenced
ICP response value for Ni in NCSC21,857SI Table
Exact Reported
2 · Supporting information · Table S1
Ni content in NCSC21.5 wt%Text
Exact Reported
8 · 3.1 · Table S1 referenced

Raman spectroscopy

NCSC · Powder

Raman spectra of NCSC and NCS.

Context
target composite versus sulfide control
Measurement source
8 · 3.1 · Fig. 4e
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Raman D band1335 cm-1Text
Exact Reported
8 · 3.1 · Fig. 4e
Raman G band1597 cm-1Text
Exact Reported
8 · 3.1 · Fig. 4e
ID/IG ratio0.98Text
Exact Reported
8 · 3.1 · Fig. 4e

XPS

NCSC · Powder

Survey and high-resolution Ni 2p, Co 2p and S 2p spectra of NCSC and NCS.

Context
target composite versus sulfide control
Measurement source
8 · 3.1 · Fig. 5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NCS Co2+/Co3+ ratio from Co 2p1/21.406SI Table
Exact Reported
3 · Supporting information · Table S4
NCS Co2+/Co3+ ratio from Co 2p3/20.544SI Table
Exact Reported
3 · Supporting information · Table S4
NCS Ni2+/Ni3+ ratio from Ni 2p1/20.757SI Table
Exact Reported
3 · Supporting information · Table S4
NCS Ni2+/Ni3+ ratio from Ni 2p3/20.523SI Table
Exact Reported
3 · Supporting information · Table S4
NCSC Co2+/Co3+ ratio from Co 2p1/23.001SI Table
Exact Reported
3 · Supporting information · Table S4
NCSC Co2+/Co3+ ratio from Co 2p3/21.713SI Table
Exact Reported
3 · Supporting information · Table S4
NCSC Ni2+/Ni3+ ratio from Ni 2p1/20.947SI Table
Exact Reported
3 · Supporting information · Table S4
NCSC Ni2+/Ni3+ ratio from Ni 2p3/20.750SI Table
Exact Reported
3 · Supporting information · Table S4
Co2+ 2p binding energies in NCSC781.8 and 798.0 eVText
Exact Reported
8 · 3.1 · Fig. 5c
Co3+ 2p binding energies in NCSC778.4 and 793.8 eVText
Exact Reported
8 · 3.1 · Fig. 5c
Ni2+ 2p3/2 binding energy in NCSC853.1 eVText
Exact Reported
8 · 3.1 · Fig. 5b
Ni3+ 2p3/2 binding energy in NCSC855.8 eVText
Exact Reported
8 · 3.1 · Fig. 5b
S 2p1/2 sulfur-vacancy binding energy164.2 eVText
Exact Reported
8 · 3.1 · Fig. 5d