two-point probe conductivity from I-V curve
pressed pellet [(Zn(DMF))2(TTFTC)(DPNI)] · Pellet
Pressed pellet between FTO plates with conductive silver epoxy; AMETEK Solartron Analytical Modulab Potentiostat; potential range +3 to -3 V; sweep rate 10 mV s^-1; room temperature.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| room-temperature pressed-pellet conductivityMarked as a best value within this paper | 2 x 10^-5 S cm^-1 | — | — | Text Rounded Reported | p004 / journal page 25775 · Results and discussion · Fig. S5 |