Other — Ionic Liquid-Laden Zn-MOF-74-Based Solid-State Electrolyte for Sodium Batteries

Measurement evidence

Other

Ionic Liquid-Laden Zn-MOF-74-Based Solid-State Electrolyte for Sodium Batteries · Mirandona-Olaeta A., Goikolea E., Lanceros-Mendez S. et al. · Batteries · 2023 · 588

1 measurement group · 22 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

TGA/DSC thermal analysis

IL0.5@MOF (0.5:1) · Pellet

Approximately 10 mg sample, 5 deg C min-1 in air, 30-700 deg C, NETZSCH STA 449F3 or SDT 2960 Simultaneous DSC-TGA

Temperature
303-973
Atmosphere
air
Context
MOF and IL@MOF thermal stability series
Measurement source
p004 / journal page 4 · 2.3 Physicochemical Characterization Techniques · Figure 3; Tables S1-S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
IL0.5@MOF decomposition temperature T1285 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.6@MOF decomposition temperature T1290 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.8@MOF decomposition temperature T1295 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL@MOF decomposition temperature T1300 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
MOF decomposition temperature T1275 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.5@MOF decomposition temperature T2445 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.6@MOF decomposition temperature T2450 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.8@MOF decomposition temperature T2440 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL@MOF decomposition temperature T2435 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
MOF decomposition temperature T2380 deg C——SI Table
Exact Reported
p002 · Supporting information · Table S2
IL0.5@MOF first-stage water mass loss19 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL0.6@MOF first-stage water mass loss18 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL0.8@MOF first-stage water mass loss17 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL@MOF first-stage water mass loss13 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
MOF first-stage water mass loss10 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL0.5@MOF Zn-MOF-74 decomposition mass loss contribution46 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL0.6@MOF Zn-MOF-74 decomposition mass loss contribution47 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL0.8@MOF Zn-MOF-74 decomposition mass loss contribution48 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
IL@MOF Zn-MOF-74 decomposition mass loss contribution54 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
MOF Zn-MOF-74 decomposition mass loss contribution44 %——SI Table
Exact Reported
p002 · Supporting information · Table S1
second TGA decomposition stage range275 to 445 deg C——Text
Range
p006 / journal page 6 · 3.1 Physicochemical Characterization · Figure 3; Table S2
first TGA decomposition/water-loss stage upper temperaturewater loss up to 100 deg C——Text
Rounded Reported
p006 / journal page 6 · 3.1 Physicochemical Characterization · Figure 3; Table S1