Electrical Transport — Photoactivated conductive MOF thin film arrays on micro-LEDs for chemiresistive gas sensing

Measurement evidence

Electrical Transport

Photoactivated conductive MOF thin film arrays on micro-LEDs for chemiresistive gas sensing · Lee K., Jo Y.-M., Sohn M.S. et al. · Nature Communications · 2025 · 9612

1 measurement group · 8 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Two-probe DC resistance in air

CuHHTP-5C · Thin Film

Non-emissive sensors measured in gas-sensing chamber; dry air stabilisation; DAQ970A multimeter.

Temperature
room temperature
Atmosphere
air
Geometry
Au interdigitated electrode; 10 nm Cr / 200 nm Au IDE; two-probe DC resistance
Context
pristine CuHHTP-xC optimisation series
Measurement source
9 · Methods - Gas-sensing experiments of non-emissive sensors · Fig. 2e
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CuHHTP-11C resistance in air179621.42 Ohm averageSD 35435.31426543172 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
CuHHTP-15C resistance in air103443.588425 Ohm averageSD 18967.960950458193 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
CuHHTP-1C resistance in air26934219.8 Ohm averageSD 6994812.6 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
CuHHTP-3C resistance in air2981038.8833333333 Ohm averageSD 474758.7097878222 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
CuHHTP-5C resistance in air782047.565 Ohm averageSD 207865.77528185694 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
CuHHTP-7C resistance in air552761.0596666667 Ohm averageSD 76147.1456339228 OhmSI Table
Exact Reported
sheet Figure 2e · Source data · Figure 2e
Resistance decrease rate cycles 1 to 558.8% per cycleText
Rounded Reported
4 · Results · Fig. 2e
Resistance decrease rate after cycle 519.4% per cycleText
Rounded Reported
4 · Results · Fig. 2e