Spectroscopy — Growth and Characterisation of Copper Complex of 2, 4, 6-Trioxypyrimidine: A Novel Luminescent and Active Pharmaceutical Material in Metal Organic Framework

Measurement evidence

Spectroscopy

Growth and Characterisation of Copper Complex of 2, 4, 6-Trioxypyrimidine: A Novel Luminescent and Active Pharmaceutical Material in Metal Organic Framework · Vineeth V.T., Divya R., Bijini B.R. et al. · Journal of Inorganic and Organometallic Polymers and Materials · 2021 · 426-436

3 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

FTIR spectroscopy using KBr pellets on Thermo Nicolet Avatar 370 spectrometer

Grown emerald coloured CuB single crystal · Single Crystal

4000-400 cm^-1 range; 4 cm^-1 resolution.

Context
Pristine CuB crystal
Measurement source
427 · 2.2 Characterisation · Figure 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu-O coordination band476 cm^-1Text
Exact Reported
428 · 3.2 FT-IR Spectral Analysis · Figure 2
OH stretching vibration of coordinated water3408 cm^-1Text
Exact Reported
428 · 3.2 FT-IR Spectral Analysis · Figure 2

Photoluminescence spectroscopy using Horiba USA Fluorolog 3 TCSPC with 450 W xenon arc lamp

Grown emerald coloured CuB single crystal · Single Crystal

PL emission recorded over 350-700 nm at excitation wavelength 320 nm; CIE chromaticity calculated from the emission.

Context
Pristine CuB crystal
Measurement source
433 · 3.7 Photoluminescence · Figures 14-15
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CIE chromaticity x coordinateapproximately 0.17 from Figure 15visual estimate +/-0.02Visual Estimate
Approximate
433 · 3.7 Photoluminescence · Figure 15
CIE chromaticity y coordinateapproximately 0.21 from Figure 15visual estimate +/-0.02Visual Estimate
Approximate
433 · 3.7 Photoluminescence · Figure 15
PL excitation wavelength320 nmText
Exact Reported
433 · 3.7 Photoluminescence · Figure 14
Maximum PL emission wavelengthMarked as a best value within this paper435 nmText
Exact Reported
433 · 3.7 Photoluminescence · Figure 14
PL shoulder wavelength514 nmText
Exact Reported
433 · 3.7 Photoluminescence · Figure 14

UV-Vis NIR absorption/reflectance spectroscopy using Varian Cary 5000

Grown emerald coloured CuB single crystal · Single Crystal

Reported instrument range 200-2000 nm; optical band gap, extinction coefficient, refractive index, and optical conductivity calculated from spectra/reflectance.

Context
Pristine CuB crystal
Measurement source
427 · 2.2 Characterisation · Figures 9-13
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Optical band gap from Tauc plotMarked as a best value within this paper1.57 eVText
Exact Reported
432 · 3.6 UV-Vis NIR Spectral Studies · Figure 10
Band gap range inferred from extinction coefficient graph1.54-2.42 eVText
Range
433 · 3.6 UV-Vis NIR Spectral Studies · Figure 11
Refractive index corresponding to 1.57 eV band gap1.367Text
Exact Reported
433 · 3.6 UV-Vis NIR Spectral Studies · Figure 12
Absorption charge-transfer peak348 nmText
Exact Reported
432 · 3.6 UV-Vis NIR Spectral Studies · Figure 9
d-d transition absorption band521-913 nm, focus at 776 nmText
Range
432 · 3.6 UV-Vis NIR Spectral Studies · Figure 9