Impedance humidity sensing
CoCa.nH2O powder/pellet humidity sensor samples · Pellet
Powder pellets and unpressed powder cycled between 55% and 95% RH at 1 kHz and 0.1 V.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Round powder pellet sensor equilibration time | >600 s for round pellet | — | > | Text Range | main p.7, article p.8122 · Humidity Sensing Properties · SI Figure S22a |
| Square powder pellet sensor equilibration time | >200 s for square pellet | — | > | Text Range | main p.7, article p.8122 · Humidity Sensing Properties · SI Figure S22b |
| Unpressed powder sensor recovery time | about 76 s | — | about | Text Approximate | main p.7, article p.8122 · Humidity Sensing Properties · SI Figure S22c |
| Unpressed powder sensor response time | about 62 s | — | about | Text Approximate | main p.7, article p.8122 · Humidity Sensing Properties · SI Figure S22c |