Spectroscopy — A conductive anionic Co-MOF cage with zeolite framework for supercapacitors

Measurement evidence

Spectroscopy

A conductive anionic Co-MOF cage with zeolite framework for supercapacitors · Du W., Bai Y.-L., Yang Z. et al. · Chinese Chemical Letters · 2020 · 2309-2313

2 measurement groups · 24 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Energy-dispersive X-ray spectroscopy (EDS)

Co-MOF on Ni foam · Electrode

EDS-derived metal atomic percentages and Ni/Co ratios summarised for Co-MOF and CTAB series.

Context
Co-MOF and CTAB-modified Co-MOF electrodes
Measurement source
main p.3 · Results and discussion · Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-CTAB-1 Co atomic percentage5.03%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-1 Ni atomic percentage1.80%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-1 Ni/Co atomic ratio35.79%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-2 Co atomic percentage7.22%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-2 Ni atomic percentage3.13%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-2 Ni/Co atomic ratio43.35%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-4 Co atomic percentage7.39%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-4 Ni atomic percentage3.21%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-4 Ni/Co atomic ratio43.43%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-6 Co atomic percentage7.61%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-6 Ni atomic percentage3.68%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-6 Ni/Co atomic ratio48.35%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-8 Co atomic percentage6.21%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-8 Ni atomic percentage3.38%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-CTAB-8 Ni/Co atomic ratioMarked as a best value within this paper54.43%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-MOF Co atomic percentage11.45%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-MOF Ni atomic percentage4.45%Table
Exact Reported
main p.3 · Results and discussion · Table 1
Co-MOF Ni/Co atomic ratio38.86%Table
Exact Reported
main p.3 · Results and discussion · Table 1

X-ray photoelectron spectroscopy, ESCALAB250Xi

Co-MOF on Ni foam · Electrode

Full survey plus high-resolution Co 2p and Ni 2p spectra for as-synthesised Co-MOF sample.

Context
Co-MOF grown on Ni foam
Measurement source
main p.3 · Results and discussion · Fig. 2b-d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co 2p1/2 binding energy797.2 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2c
Co 2p3/2 binding energy781.9 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2c
Co 2p spin energy separation15.3 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2c
Ni 2p1/2 binding energy874.3 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2d
Ni 2p3/2 binding energy856.4 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2d
Ni 2p spin energy separation17.9 eVText
Exact Reported
main p.3 · Results and discussion · Fig. 2d