Sensing Application — Epitaxial Self-Assembly of Interfaces of 2D Metal-Organic Frameworks for Electroanalytical Detection of Neurotransmitters

Measurement evidence

Sensing Application

Epitaxial Self-Assembly of Interfaces of 2D Metal-Organic Frameworks for Electroanalytical Detection of Neurotransmitters · Stolz R.M., Kolln A.F., Rocha B.C. et al. · ACS Nano · 2022 · 13869-13883

1 measurement group · 11 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

differential pulse adsorption stripping voltammetry (DPASV)

Ni3(HHTP)2 {001} oriented film on GCE · Electrode

Measurement source
54 · DPASV of DA on Ni3(HHTP)2 · Figure S43
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DA LOD with 50 uM DOPAC on Ni {001} (main text)381Text
Exact Reported
9 · DPASV sensing · Figure 5 discussion
DA LOD with 5 uM DOPAC on Ni {001}48Figure Axis
Approximate
55 · DPASV sensing · Figure S44
DA LOD in simulated CSF on Ni {001}214 +/- 48Text
Exact Reported
56 · DPASV sensing · Figure S45
DA LOD with 50 uM DOPAC on Ni {001} (SI figure)185Figure Axis
Approximate
55 · DPASV sensing · Figure S44
DA LOD in simulated CSF run 1180Figure Axis
Approximate
56 · DPASV sensing · Figure S45
DA LOD in simulated CSF run 2180Figure Axis
Approximate
56 · DPASV sensing · Figure S45
DA LOD in simulated CSF run 3281Figure Axis
Approximate
56 · DPASV sensing · Figure S45
DA LOD in PBS run 113.5Figure Axis
Approximate
54 · DPASV sensing · Figure S43
DA LOD in PBS run 26.4Figure Axis
Approximate
54 · DPASV sensing · Figure S43
DA LOD in PBS run 39.9Figure Axis
Approximate
54 · DPASV sensing · Figure S43
DA LOD in PBS on Ni {001}9.9 +/- 2Figure Axis
Approximate
54 · DPASV sensing · Figure S43