| DUT-67(Hf) gas response to MA at 0.5 ppm, 68% RH | 57% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 0.5 ppm, 85% RH | 44% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 0.5 ppm, 68% RH | 45% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 0.5 ppm, 85% RH | 32% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 0.5 ppm, 68% RH | 13% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 0.5 ppm, 85% RH | 20% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 1 ppm, 68% RH | 96% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 1 ppm, 85% RH | 73% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 1 ppm, 98% RH | 27% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 1 ppm, 68% RH | 75% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 1 ppm, 85% RH | 54% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 1 ppm, 98% RH | 23% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 1 ppm, 68% RH | 60% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 1 ppm, 85% RH | 47% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 1 ppm, 98% RH | 15% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 2 ppm, 68% RH | 238% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 2 ppm, 85% RH | 149% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 2 ppm, 98% RH | 42% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 2 ppm, 68% RH | 178% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 2 ppm, 85% RH | 92% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 2 ppm, 98% RH | 42% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 2 ppm, 68% RH | 136% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 2 ppm, 85% RH | 75% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 2 ppm, 98% RH | 33% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 6 ppm, 68% RH | 776% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 6 ppm, 85% RH | 453% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 6 ppm, 98% RH | 113% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 6 ppm, 68% RH | 560% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 6 ppm, 85% RH | 218% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 6 ppm, 98% RH | 97% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 6 ppm, 68% RH | 480% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 6 ppm, 85% RH | 171% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 6 ppm, 98% RH | 79% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 12 ppm, 68% RH | 1435% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 12 ppm, 85% RH | 826% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 12 ppm, 98% RH | 224% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 12 ppm, 68% RH | 1180% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 12 ppm, 85% RH | 458% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 12 ppm, 98% RH | 177% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 12 ppm, 68% RH | 918% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 12 ppm, 85% RH | 304% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 12 ppm, 98% RH | 139% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 18 ppm, 68% RH | 2374% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 18 ppm, 85% RH | 1213% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 18 ppm, 98% RH | 361% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 18 ppm, 68% RH | 1812% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 18 ppm, 85% RH | 711% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 18 ppm, 98% RH | 252% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 18 ppm, 68% RH | 1459% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 18 ppm, 85% RH | 450% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 18 ppm, 98% RH | 201% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 30 ppm, 68% RHMarked as a best value within this paper | 4191% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 30 ppm, 85% RH | 2027% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to MA at 30 ppm, 98% RH | 554% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 30 ppm, 68% RH | 3059% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 30 ppm, 85% RH | 1083% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to DMA at 30 ppm, 98% RH | 396% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 30 ppm, 68% RH | 2354% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 30 ppm, 85% RH | 714% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) gas response to TMA at 30 ppm, 98% RH | 302% | — | — | Table Exact Reported | 3041 · Sensing Properties · Table 3 |
| DUT-67(Hf) MA detection limit at 25 deg C and 68% RH | 0.5 ppm | — | — | Text Exact Reported | 3036/3044 · Abstract / Conclusions |
| DUT-67(Hf) DMA detection limit at 25 deg C and 68% RH | 0.5 ppm | — | — | Text Exact Reported | 3036/3044 · Abstract / Conclusions |
| DUT-67(Hf) TMA detection limit at 25 deg C and 68% RH | 0.5 ppm | — | — | Text Exact Reported | 3036/3044 · Abstract / Conclusions |
| dry-air proton conductivity/sensing capability | no conductivity and no volatile-amine sensing capability in dry air at 25 deg C | — | — | Text Qualitative | 3042 · Sensing Properties |